§ 60.3076. What equations must I use?

469 words·~2 min read·/us/cfr/t40/s§ 60.3076·

A research copy — for the controlling text, always check the official state or federal source. Not legal advice.

(a)Percent oxygen. Adjust all pollutant concentrations to 7 percent oxygen using Equation 1 of this section. Where: Cadj = pollutant concentration adjusted to 7 percent oxygen Cmeas = pollutant concentration measured on a dry basis (20.9-7) = 20.9 percent oxygen-7 percent oxygen (defined oxygen correction basis) 20.9 = oxygen concentration in air, percent %O2 = oxygen concentration measured on a dry basis, percent
(b)Capacity of a very small municipal waste combustion unit. For very small municipal waste combustion units that can operate continuously for 24-hour periods, calculate the unit capacity based on 24 hours of operation at the maximum charge rate. To determine the maximum charge rate, use one of two methods:
(1)For very small municipal waste combustion units with a design based on heat input capacity, calculate the maximum charging rate based on the maximum heat input capacity and one of two heating values:
(i)If your very small municipal waste combustion unit combusts refuse-derived fuel, use a heating value of 12,800 kilojoules per kilogram (5,500 British thermal units per pound).
(ii)If your very small municipal waste combustion unit combusts municipal solid waste, use a heating value of 10,500 kilojoules per kilogram (4,500 British thermal units per pound).
(2)For very small municipal waste combustion units with a design not based on heat input capacity, use the maximum design charging rate.
(c)Capacity of a batch very small municipal waste combustion unit. Calculate the capacity of a batch OSWI unit as the maximum design amount of municipal solid waste it can charge per batch multiplied by the maximum number of batches it can process in 24 hours. Calculate the maximum number of batches by dividing 24 by the number of hours needed to process one batch. Retain fractional batches in the calculation. For example, if one batch requires 16 hours, the OSWI unit can combust 24/16, or 1.5 batches, in 24 hours.
(d)Carbon monoxide pollutant rate. When hourly average pollutant rates
(Eh)are obtained (e.g., CEMS values), compute the rolling average carbon monoxide pollutant rate
(Ea)for each 12-hour period using the following equation: Equation 2 to Paragraph
(d)Where: Ea = Average carbon monoxide pollutant rate for the 12-hour period, parts per million
(ppm)corrected to 7 percent O2. Note that a 12-hour period may include CEMS data during startup and shutdown, as defined in the subpart, in which case the period will not consist entirely of data that have been corrected to 7 percent O2. Ehj = Hourly arithmetic average pollutant rate for hour “j,” ppm corrected to 7 percent O2. CEMS data during startup and shutdown, as defined in the subpart, are not corrected to 7 percent oxygen, and are measured at stack oxygen content. [70 FR 74907, Dec. 16, 2005, as amended at 90 FR 27966, June 30, 2025]
★   the supreme law of the land   ★
Don't Tread on Me
E Pluribus Unum — out of many, one

"If you don't know your rights, you don't have any."

Marginalia · a citizen's law index
A research desk, not legal advice. Always read the cited source before relying on a summary.
Questions or an issue? support@self-law.org
disclaimerMarginalia is a research index, not a law firm. Nothing on this site is legal, tax, or financial advice and no attorney–client relationship is formed by using it. Statutes, regulations, and case law change; summaries, search results, AI output, and member posts may be incomplete, out of date, or wrong. Any interpretation drawn from material on this site should be validated by a licensed attorney in your jurisdiction before you act on it.